Product Features:
· Wide range of applicable flow meters and fluid media
· Automatic conversion of flow units and automatic calculation of flow coefficients for differential pressure flow meters
· Steam density is calculated based on the IAPWS-IF97 formula, with automatic identification of superheated and saturated steam states
· Emergency fault tolerance function: Compensatory calculation using emergency parameter values when temperature or pressure signals are abnormal
· Debugging and calculation function: View raw transmitter/sensor signal values and intermediate parameters of flow calculation
· Audit record: Power failure recording function
· Alarm list: Supports recording alarm information of instantaneous or accumulated values such as flow rate, temperature, pressure, differential pressure/frequency/volume/mass
· Accumulation report: Supports shift, daily, monthly and yearly reports of accumulated flow
· Communication function: Compliant with standard Modbus RTU protocol, supporting RS485 and RS232C communication interfaces
Standard Modbus TCP protocol supports Ethernet RJ45 interface
· Transmission function: Supports standard current transmission output with selectable signal source channels
· Report backup function: Supports backup of all accumulation reports
· Import and export function: Supports import and export of instrument configuration parameters
· Timed printing function: Supports timed printing of data including flow rate, temperature, pressure and accumulation values
Non-standard Customization Support:
· Supports OEM faceplate customization and boot interface customization
· Supports customization of flow algorithms and operation interfaces
· Supports customization of signal types and technical parameters
· Supports customization of F-LINK management system
Installation Methods:

Installation Method:
· Step 1: Push the instrument forward into the mounting hole from the front of the mounting panel (steel plate is required). The thickness of the mounting panel is (1.5~6.5) mm.
· Step 2: Install the mounting brackets supplied with the instrument as shown in the figure above (install one bracket on each of the left and right sides of the instrument; M4 standard screws shall be used for the instrument mounting brackets).
· Step 3: After the main body of the instrument is installed, connect the signal lines and power lines.
F3000X Premium Flow Accumulator Instrument English User Manual.pdf
Next : F3001X Deluxe Flow Totalizer
Previous : F3100D Exquisite Quantitative Controller